BIX 002 CUSTOMER BURNER TEST

The BIX 002 was configured with a refillable gas tank, using a Go System butane/propane gas mixture with a 70/30 ratio. To assess the burner’s performance and determine whether it was operating correctly, we carried out a series of tests using three different jet sizes: No. 5, No. 8 and No. 16.

Each jet was tested to compare the resulting flame intensity and observe any differences in burner performance. This process allowed us to evaluate how effectively the burner operated with each jet size and to establish whether the burner was functioning as intended or if a potential fault was affecting its performance.

 

TESTING THE 002 BURNER WITH A NUMBER 5 JET

A blue flame was achieved easily when using the No. 5 jet, indicating that the burner was able to produce the desired flame under these test conditions. During testing, the jet holder was initially pushed fully into position before being withdrawn by approximately 3 mm to adjust its position and optimise the flame.

This adjustment produced a stable blue flame, which can be clearly observed in the accompanying video footage and images. These visual records document the setup and demonstrate the burner’s performance with the No. 5 jet.

PICTURE OF BURNER RUNNING WITH A NUMBER 5 JET

TESTING THE 002 BURNER WITH A NUMBER 8 JET

When using the No. 8 jet, the burner was also straightforward to set up, and achieving an optimal blue flame was relatively easy. The flame could be adjusted by gradually withdrawing the jet holder from its fully inserted position until the desired combustion characteristics were achieved.

During testing, we observed that the jet holder needed to be pulled back by approximately 10 mm from its fully inserted position. This measurement was taken between the end of the 1/8-inch gas pipe and the beginning of the mixing tube. At this position, the burner was able to produce the desired blue flame, demonstrating that the No. 8 jet could also be set up and adjusted without significant difficulty.

PICTURE OF BURNER RUNNING WITH A NUMBER 8 JET

TESTING THE 002 BURNER WITH A NUMBER 16 JET

Testing the BIX 002 burner with the No. 16 jet proved to be somewhat more challenging than with the smaller jet sizes. Achieving a completely blue flame was more difficult, with approximately half of the burner producing a faint yellow flame.

However, the overall flame was considerably more intense, larger in size and noticeably hotter than those produced by the No. 5 and No. 8 jets.

Despite the increased flame intensity and heat output, we did not observe the ceramic element overheating during testing. Once the flame had been adjusted to its optimum position, the ceramic did not glow red. This suggests that, under the conditions tested, the No. 16 jet may be a suitable option for live steam applications requiring a higher heat output.

Although achieving a consistently blue flame was more difficult with this jet size, the increased heat intensity may be beneficial for applications where greater burner performance is required. Further testing under different operating conditions would help establish the most suitable settings and confirm long-term performance.

PICTURE OF BURNER RUNNING WITH A NUMBER 16 JET

Our conclusion - Burner testing

 

Following receipt of your BIX 002 burner, we have carried out a series of tests to investigate the difficulty you experienced when setting up the burner and achieving the correct blue flame. Our objective was to establish whether there was a fault with the burner itself or whether the issue was related to its setup and adjustment.

We tested the burner using a refillable BIX gas tank containing a Go System butane/propane mixture in a 70/30 ratio. To assess its performance under different operating conditions, we tested three jet sizes: No. 5, No. 8 and No. 16. Each configuration was assessed for ease of setup, flame characteristics and overall burner performance.

Our testing demonstrated that the BIX 002 was capable of producing a blue flame with both the No. 5 and No. 8 jets. With the No. 5 jet, a blue flame was achieved readily by pushing the jet holder fully into position and then withdrawing it by approximately 3 mm. With the No. 8 jet, achieving the desired blue flame was also straightforward, although the jet holder required a greater adjustment of approximately 10 mm from its fully inserted position. These results demonstrate that the burner can be adjusted to achieve the correct flame when the jet holder is positioned appropriately.

We also tested the burner with the No. 16 jet. Although achieving a completely blue flame was more challenging, the burner produced a substantially larger, more intense and noticeably hotter flame. Despite the increased heat output, we did not observe the ceramic element overheating or glowing red once the flame had been optimised during our tests.

Based on these tests, we have found no evidence of a fault with the BIX 002 burner. It operated successfully with the No. 5 and No. 8 jets and demonstrated that its flame characteristics could be adjusted through correct positioning of the jet holder. The large yellow flame you reported is consistent with a burner that has not been adjusted to its optimum operating position, although the flame colour alone cannot conclusively establish the cause.

We appreciate that you have experienced difficulty setting up the burner, and we understand how frustrating this can be. However, our testing indicates that the burner itself is functioning as expected, and we have therefore been unable to identify a fault that would warrant repair or replacement.

We propose to return the tested BIX 002 burner to you, together with our test findings and the troubleshooting guidance below. We recommend following the setup procedure carefully, paying particular attention to the position of the jet holder in relation to the mixing tube. Small adjustments can make a significant difference to the resulting flame, and the correct position will depend on the jet size being used.

We hope that these findings and the additional guidance will help you achieve the intended blue flame and obtain satisfactory performance from your BIX 002 burner.

Troubleshooting – Achieving the Correct Blue Flame

If you experience difficulty achieving a blue flame with your BIX 002 burner, we recommend reviewing the setup procedure in the supplied user instructions and paying particular attention to the position of the jet holder.

Step 1 – Check the jet and gas supply

Ensure that the correct jet is fitted securely and sealed with either PTFE tape or a non hardening jointing compound like Hylotyte Red.

Ensure that the gas supply is compatible with the burner. For our tests, we used a Go System butane/propane mixture with a 70/30 ratio. Confirm that the gas connections are secure and that the burner is assembled in accordance with the supplied instructions.

Step 2 – Check the position of the jet holder

The position of the jet holder is particularly important. If it is pushed too far into the mixing tube, the burner may produce a large yellow flame rather than the desired blue flame. The jet holder should not simply be pushed fully into the mixing tube and left in that position; it may need to be withdrawn to achieve the correct gas and air mixture.

During our testing, we obtained the following results:

  • No. 5 jet: A blue flame was achieved by withdrawing the jet holder approximately 3 mm from its fully inserted position.

  • No. 8 jet: A blue flame was achieved with the jet holder withdrawn approximately 10 mm from its fully inserted position, measured between the end of the 1/8-inch gas pipe and the start of the mixing tube.

  • No. 16 jet: Achieving a completely blue flame was more difficult, and the flame was considerably larger and hotter. Additional care is required when adjusting this configuration.

These measurements are the positions observed during our tests and should be treated as useful starting points rather than guaranteed settings for every installation.

Step 3 – Adjust the flame gradually

Following the instructions for the lighting procedure, make very small adjustments to the jet holder and allow the flame to stabilise after each adjustment. Observe the flame carefully and aim for a consistent blue flame rather than a large, predominantly yellow flame. Avoid making large adjustments all at once, as this can make it more difficult to identify the optimum position.

Step 4 – Check the burner and ceramic element

Once the flame has stabilised, observe the flame pattern and the ceramic element. Do not assume that a larger flame necessarily indicates better performance. The objective is to achieve the intended combustion characteristics while operating the burner within its specified limits.

If the flame remains predominantly yellow despite careful adjustment, extinguish the burner and allow it to cool before checking the assembly against the supplied instructions. Do not continue operating the burner in an abnormal condition or attempt to make adjustments while it is hot.

Step 5 – Refer to the supplied user instructions

Please use this guidance alongside the original BIX user instructions, which contain the intended setup and operating procedure. If the burner still does not produce the expected flame after following these steps, please contact us with details of the jet size being used and, if possible, photographs or a short video showing the jet holder position and the flame. This will help us assess the setup more accurately and advise on the next steps.

For safety, carry out testing in a suitable, well-ventilated area, keep combustible materials away from the burner and follow all gas-handling precautions in the manufacturer’s instructions.

© 2026 FOREST CLASSICS All rights reserved

WE ACCEPT ALL MAJOR CREDIT AND DEBIT CARDS, AND OVER-THE-PHONE PAYMENTS

we accept google pay apple pay paypal and all major credit and debit cards
 FOREST CLASSICS IS A PARTICIPANT IN THE AMAZON EU ASSOCIATES PROGRAMME, AN AFFILIATE ADVERTISING PROGRAMME DESIGNED TO PROVIDE A MEANS FOR SITES TO EARN ADVERTISING FEES BY ADVERTISING AND LINKING TO AMAZON.CO.UK AND AMAZON.COM. THESE LINKS DO NOT INCREASE YOUR FINAL PRICE PAID TO AMAZON AND THEY REALLY HELP OUT FOREST CLASSICS, AND HELP US TO STAY ONLINE.

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping